Morrison Bros Fig. 351S & 748A Flame Arrester/Pressure Vacuum Vent

$1,080.61
SKU 351S--0200 AV
Item Numbers

Item Series:

Morrison Bros Fig. 351S & 748A Flame Arrester/Pressure Vacuum Vent

Downloadable Resources:

FIG 351S & FIG 748A SPECIFICATION SHEET

Product Ordering Information:

Products Description & Features:

Description:

Flame arresters provide a positive barrier that keeps flames from passing through the pressure vacuum vent line into a storage tank’s vapor space.

WARNING: Do not use with acetylene, carbon disulfide, Ethelene oxide or hydrogen gases. For use with normal hydrocarbon flames such as gasoline in air. Routine inspection is required to ensure airways are clear and free of debris. Blocked airways can cause structural deformation of the tank.

WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Morrison tank vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airflow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank. Normal vents such as pressure vacuum and updraft vents for aboveground storage tanks should be sized according to NFPA 30 (2018) 21.4.3

Standard Features:

• Directs vapors outward and upward in accordance with NFPA 30 • Protects the vent line from debris and insects • Tri-polar mounting screws for mounting exhaust hood in any of
three positions • Optional pressure discharge hood facilitates piping pressure relief
to desired discharge point.

Construction Details:

351S • Body and cover... cast iron, • Arrester grid housing... brass • Arrester plates... stainless steel.

748A • Body and hood... aluminum • Poppets and seats... brass • Screens... stainless steel.

Restrictions And Warnings:

Do not use with acetylene, carbon disulfide, Ethelene oxide or hydrogen gases. For use with normal hydrocarbon flames such as gasoline in air.

Routine inspection is required to ensure airways are clear and free of debris. Blocked airways can cause structural deformation of the tank.

Please inquire about product information, installation services, bulk pricing, variable lengths, quotes or any questions you may have!